Standard of Quality

InterNACHI Standard of Practice

Evaluating the structural and system integrity of a property from top to bottom. NextDay Inspect® strictly adheres to the Standards of Practice defined by the International Association of Certified Home Inspectors (InterNACHI) to ensure a comprehensive, detailed, and professional visual examination.

Non-Invasive
Visual Inspection
Certified NextDay Inspect Home Inspector reviewing residential property structure
Introduction

Scope of the Agreement

About the InterNACHI Standards of Practice

These Standards of Practice apply to residential properties with four or fewer units. They define the minimum requirements of a home inspection. A professional inspection outlines the visible systems and components that are both observed and deemed material by the inspector at the exact time and date of the inspection.

Section 1

Definitions & Scope

1.1 Home Inspection Scope

A home inspection is a non-invasive, visual examination of the accessible areas of a residential property designed to identify defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector.

Modifications: The scope of work may be modified by agreement between the Client and Inspector prior to the inspection process.

Context of Time: The inspection is based on observations made on the date of the inspection. It is not a prediction of future conditions.

Observed Defects Only: The inspection will not reveal every issue that exists or ever could exist, but only those material defects observed on the inspection date.

1.2 Material Defect Definition

A material defect is a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people.

Useful Life Expectancy: The fact that a system or component is near, at, or beyond the end of its normal, useful life is not, in itself, a material defect.

1.3 Inspection Report

A home inspection report shall identify, in written format, defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector.

Recommendations: Reports may include additional comments and recommendations for correction or monitoring.

Section 2

Limitations, Exceptions & Exclusions

  • An inspection is not technically exhaustive.
  • An inspection will not identify concealed or latent defects.
  • An inspection will not deal with aesthetic concerns or cosmetics.
  • An inspection does not determine property suitability for any use.
  • An inspection does not determine market value or marketability.
  • An inspection does not determine property insurability.
  • An inspection does not determine purchase advisability.
  • An inspection does not determine life expectancy of components.
  • An inspection does not include items not permanently installed.
  • Applied to properties with 4 or fewer residential units & garages.

The inspector is not required to determine:

  • Property boundary lines or encroachments.
  • Condition of any component that is not readily accessible.
  • Service life expectancy of any component or system.
  • Size, capacity, BTU, performance or efficiency.
  • Cause or reason of any condition.
  • Reason for correction, repair, or replacement.
  • Future conditions.
  • Compliance with building codes or regulations.
  • Presence of rodents, birds, insects or pests.
  • Presence of mold, mildew or fungus.
  • Airborne hazards, including radon and air quality.
  • Lead paint, asbestos, toxic drywall or env. hazards.
  • Electromagnetic fields or hazardous waste conditions.
  • Manufacturer recalls or installation conformance.
  • Acoustical properties.
  • Correction, replacement or repair cost estimates.
  • Estimates of system operating costs.

The inspector is not required to operate:

  • Any system that is shut down or does not function properly.
  • Any system that does not turn on with normal operating controls.
  • Any shut-off valves or manual stop valves.
  • Electrical disconnects or over-current protection devices.
  • Alarm systems, moisture meters, or gas detectors.
  • Low-voltage electrical systems (phones, cable, satellite, antennae, lights).

The inspector is not required to perform actions like:

  • Move personal items, rugs, carpeting, furniture, window coverings, or plants.
  • Dismantle, open, or uncover any system or component.
  • Enter crawlspaces, attics, or areas that may be unsafe or inaccessible.
  • Inspect underground items (sprinklers, underground storage tanks).
  • Walk on roof surfaces, climb ladders, or negotiate with pets.
  • Inspect decorative items, security systems, intercoms, or common elements.
  • Offer guarantees, warranties, engineering services, or trade work.
  • Research property history, structural age, or alteration potential.
Section 3

Standards of Practice

3.1 Roof

Shall Inspect

  • The roof-covering materials from ground level or the eaves.
  • The gutters and downspouts.
  • Vents, flashing, skylights, chimney, and other roof penetrations.
  • General structure of roof from readily accessible panels/doors/stairs.

Shall Describe

  • The type of roof-covering materials.

Correction Needed

  • Observed indications of active roof leaks.

Not Required To

  • Walk on any roof surface.
  • Predict roof service life expectancy.
  • Inspect underground downspout diverter drainage pipes.
  • Remove snow, ice, or debris prohibiting inspection.
  • Move insulation or perform water test.
  • Confirm proper fastening/installation of roof covering.

3.2 Exterior

Shall Inspect

  • Exterior wall-covering materials, flashing and trim.
  • Eaves, soffits, and fascia.
  • Representative number of windows and all exterior doors.
  • Adjacent walkways, driveways, stairs, stoops, and ramps.
  • Porches, patios, decks, balconies, and carports.
  • Railings, guards, and handrails.
  • Grading, surface drainage, vegetation, and retaining walls.

Shall Describe

  • The type of exterior wall-covering materials.

Correction Needed

  • Improper spacing between intermediate balusters, spindles, and rails.

Not Required To

  • Inspect screens, shutters, storm windows, fences, or accent lighting.
  • Inspect items not visible or accessible from the ground (flashing).
  • Identify geological, hydrological, soil, or erosion-control details.
  • Inspect swimming pools, spas, wastewater treatments, or septic systems.
  • Inspect irrigation, wells, solar, wind, or geothermal installations.
  • Determine integrity of multi-pane window glazing/thermal seals.

3.3 Basement, Foundation, Crawlspace & Structure

Shall Inspect

  • The foundation.
  • The basement and crawlspace.
  • All structural components.

Shall Describe

  • The type of foundation.
  • The location of access to the under-floor space.

Correction Needed

  • Wood in contact with or near soil.
  • Observed indications of active water penetration.
  • Indications of foundation movement (cracks, out-of-square frames, unlevel floors).
  • Improper cutting, notching, or boring of framing members.

Not Required To

  • Enter crawlspaces that are not readily accessible or unsafe.
  • Move stored items, furniture, or debris.
  • Operate sump pumps with inaccessible floats.
  • Identify size, spacing, span, or adequacy of structural members.
  • Provide engineering or architectural services.

3.4 Heating

Shall Inspect

  • The heating system using normal operating controls.

Shall Describe

  • Location of thermostat for heating system.
  • The system energy source and heating method.

Correction Needed

  • Any heating system that did not operate.
  • Heating systems deemed inaccessible.

Not Required To

  • Inspect flues/chimney interiors, heat exchangers, combustion air, humidifiers, or electronic filters.
  • Inspect fuel tanks or concealed supply lines.
  • Determine system capacity, BTU sizing, air flow balance, or heat uniformity.
  • Light pilot flames or bypass electronic thermostats.

3.5 Cooling

Shall Inspect

  • The cooling system using normal operating controls.

Shall Describe

  • Location of thermostat for cooling system.
  • The cooling method.

Correction Needed

  • Any cooling system that did not operate.
  • Cooling systems deemed inaccessible.

Not Required To

  • Determine BTU size, distribution balance, flow rate, or cooling uniformity.
  • Inspect portable window units, through-wall units, or electronic air filters.
  • Operate systems if ambient outdoor temperature is below 65° Fahrenheit.
  • Examine electrical current, coolant fluids, gases, or leaks.

3.6 Plumbing

Shall Inspect

  • The main water and main fuel supply shut-off valves.
  • Water heating equipment, including energy source, venting, and TPR valves.
  • Interior water supply, including fixtures and faucets by running water.
  • All toilets for proper operation by flushing.
  • Sinks, tubs, and showers for functional drainage.
  • Drain, waste, and vent systems.
  • Drainage sump pumps with accessible floats.

Shall Describe

  • Public or private water supply based on observed evidence.
  • Location of main water supply shut-off valve.
  • Location of main fuel supply shut-off valve.
  • Capacity of water heating equipment, if labeled.

Correction Needed

  • Water flow deficiencies observed in two simultaneous fixtures.
  • Incorrect hot and cold faucet installation.
  • Active plumbing leaks observed during inspection.
  • Damaged, leaking, loose, or improperly operating toilets.

Not Required To

  • Light pilot flames or operate manual stop/safety valves.
  • Determine water flow rate, pressure, volume, or water quality.
  • Open sealed access panels, inspect washing machine connections, or test shower pans.
  • Inspect water softeners, filter systems, lawn sprinklers, or fire sprinkler lines.

3.7 Electrical

Shall Inspect

  • Service drop, overhead conductors, service head, and drip loops.
  • Service mast, conduit, raceway, electric meter, and base.
  • Main service disconnect, panelboards, breakers, and fuses.
  • Service grounding, bonding, and smoke/CO detector presence.
  • Representative switches, fixtures, GFCI/AFCI receptacles (using testers).

Shall Describe

  • Main service disconnect's amperage rating, if labeled.
  • Type of wiring observed.

Correction Needed

  • Deficient service-entrance conductors (insulation or clearance).
  • Unused circuit breaker openings that are not filled.
  • Solid conductor aluminum branch-circuit wiring, if visible.
  • Deficient receptacles (unpowered, incorrect polarity, ungrounded, loose, or heat/arcing signs).
  • Absence of smoke and/or carbon monoxide detectors.

Not Required To

  • Insert tools or probes into panelboards or distribution covers.
  • Remove panel cabinet covers or dead fronts.
  • Reset breakers, test alarms, or verify service ground depth.
  • Inspect low-voltage systems, generators, solar/wind systems, or swimming pool wiring.

3.8 Fireplace

Shall Inspect

  • Accessible and visible portions of fireplaces and chimneys.
  • Lintels above fireplace openings.
  • Damper doors by manually opening and closing, if accessible.
  • Cleanout doors and frames.

Shall Describe

  • The type of fireplace.

Correction Needed

  • Hearth, extension, or chamber joint separation/damage/deterioration.
  • Manually operated dampers that did not open and close.
  • Lack of smoke or CO detector in the fireplace room.
  • Cleanouts not made of metal, concrete, or non-combustibles.

Not Required To

  • Inspect the interior of chimneys or flues, fire doors, or screens.
  • Operate gas inserts, light pilot flames, or perform smoke tests.
  • Determine draft characteristics or move fireplace contents/stoves.
  • Perform NFPA-style or Phase I fireplace inspections.

3.9 Attic, Insulation & Ventilation

Shall Inspect

  • Insulation in unfinished spaces (attics, crawlspaces, foundation).
  • Ventilation of unfinished spaces (attics, crawlspaces, foundation).
  • Mechanical exhaust systems in the kitchen, bathrooms, and laundry area.

Shall Describe

  • The type of insulation observed.
  • Approximate average depth of insulation in unfinished attics.

Correction Needed

  • General absence of insulation or ventilation in unfinished spaces.

Not Required To

  • Enter attics/spaces that are inaccessible or unsafe.
  • Move, touch, or disturb insulation or vapor retarders.
  • Break access panel seals, or identify insulation composition/R-values.
  • Activate thermostatic fans or determine ventilation adequacy.

3.10 Doors, Windows & Interior

Shall Inspect

  • Representative number of doors and windows (open/close).
  • Floors, walls, and ceilings.
  • Stairs, steps, landings, stairways, and ramps.
  • Railings, guards, and handrails.
  • Garage vehicle doors and automatic opener controls.

Shall Describe

  • Garage vehicle door as manual or auto-opener installed.

Correction Needed

  • Improper intermediate spacing of balusters/rails.
  • Faulty photo-electric garage safety sensors.
  • Windows that are fogged or show evidence of broken seals.

Not Required To

  • Inspect paint, wallpaper, carpet, or finish treatments.
  • Move furniture, appliances, rugs, or suspended tiles.
  • Evaluate security bar releases, alarms, central vacuums, or safety glass glazing.
  • Inspect saunas, kilns, small appliances, pools, or spas.

Work with Certified Professionals

Our team at NextDay Inspect® combines rigorous adherence to InterNACHI standards with modern report writing tools to provide the highest level of inspection clarity. Whether you're looking to hire our team or looking for your next career step, we are here to support.